Crónicas de cableado

Comprobación de cableado con conectores MPO: ¿Qué hay de nuevo?

Con la amplia variedad de estándares relacionados con el cableado de fibra óptica, la ausencia de las normas publicadas para la comprobación de cableado de fibra óptica terminado con conectores MPO puede venir como una sorpresa. Por último, un informe técnico (TR), escrito por este autor, está programado para su publicación en junio 2017 que proporciona ayuda en la comprobación: es TR/IEC 61282-15. Un informe técnico proporciona ayuda sobre un tema pero no tiene requisitos (por ejemplo, sin "shalls") como una norma internacional o un estándar de ANSI/TIA lo haría.

8 de marzo de 2017

How to Test Shield Integrity?

Back when Wolfenstein 3D was all the rage, we set up an exhibit at a BICSI conference where we tried to make a Cat 5 link fail by inducing noise onto it. We tried all kinds of no-no’s, such as placing the cable next to a fluorescent ballast, a large electric motor, and even the coil of a running car’s engine, yet the link provided virtually error-free 100BASE-TX performance. At that point, it didn’t seem like there would be much benefit for screened cable for the vast majority of installations.

15 de febrero de 2017

#ICYMI: Highlights from 2017 BICSI Winter

 

The 2017 BICSI Winter Conference wrapped up last week in Tampa where thousands of ICT professional from around the world had a chance to gain valuable industry knowledge and check out the latest products from nearly 180 vendors in the exhibit hall – including our new DSX-8000 CableAnalyzer.

8 de febrero de 2017

El camino hacia un comprobador de cableado de categoría 8

En enero 23, anunciamos el DSX-8000 CableAnalyzer ™ , el primer comprobador verdadero de categoría 8.  Usted puede preguntarse lo que se requiere para un comprobador de certificación “verdadero” de categoría 8 y por qué lo lanzamos ahora.

2 de febrero de 2017

Tips to Identify Copper Clad Aluminium (CCA) Cables

 

So you came across some Category 6 cable available online for practically half what you've been paying for that brand name. It claims TIA-568-C compliance, includes the UL listing mark and even has a ETL verification legend printed right on the cable. Before you get too excited, you might want to make sure that cable isn't made with copper clad aluminum (CCA).

18 de enero de 2017

Goodbye 2016. You Weren’t ALL Bad

 

All over the news and social media, 2016 has gotten a pretty bum rap.

With everything from shootings, terrorist attacks and the weirdest presidential election in history, to exploding cell phones, scary clown threats and numerous celebrity deaths, 2016 has been denoted as the worst year ever.

4 de enero de 2017

How to Save Money and Time in Testing Fibers with SmartLoop

The only way to get correct values when performing Tier 2 testing of duplex fiber links with an OTDR is via bidirectional testing that averages the measurements taken from both ends of the link.

Bidirectional testing used to involve testing the fiber from one end, walking the OTDR to the other end to test again and then averaging the two values to get the results—and it had to be done for each link.

30 de diciembre de 2016

Comprobación del nuevo comprobador de cable en 2017

 

Nuevamente es la época del año en la que analizamos lo que pronosticamos serán las tendencias mayores en pruebas en el siguiente año.

Obviamente, el Internet de las cosas (IofT) será siendo el impulsor importante en todos los cableados de redes, desde redes LAN en donde veremos más dispositivos que nunca antes residiendo en cableado de redes con pares trenzados de alambre de cobre, a los centros de datos en los cuales la demanda por enlaces de fibra de alta velocidad continúa expandiéndose conforme las empresas se enfrentan a la necesidad de acceder, transmitir y almacenar más datos que nunca antes.

14 de diciembre de 2016

¿Qué tan preciso es su juego de comprobación de pérdida óptica?

Acaba de realizar una medición de pérdida usando un Equipo de comprobación de pérdida óptica (OLTS). La medición fue realizada a un límite de prueba, el resultado fue de "PASA", y se proporcionó el margen. ¿Ha pensado acerca de cuánto margen es aceptable?

1 de diciembre de 2016