In ISO/IEC 11801:2010, the following designations can be found in the informative Annex E. (Informative = not required for compliance)

Por ejemplo:

  • U/UTP = overall unscreened cable with unscreened twisted pairs (often referred to as UTP)
  • F/UTP = overall screened cable with unscreened twisted pairs (often referred to as FTP)
  • S/FTP = overall braid screened cable with foil screened twisted pairs (often referred to as STP or PiMF)
  • SF/UTP = overall braid and foil screened cable with unscreened twisted pairs

 

Fluke Networks has adopted this in the DSX-5000 CableAnalyzer for the most used cable types: