Regla de 4 dB: DTX CableAnalyzer

A YouTube video explaining how this this works is also available from here.  

This is applicable to the following cabling standards only:
 

  • ISO/IEC 11801
  • EN 50173
  • Aus/NZ
  • JIS

When the Insertion Loss is less than 4,0 dB at the frequency point where the measurement is made, then the measurement is ignored and not evaluated against the selected Test Limit/Cabling Standard in the DTX CableAnalyzer. A menudo se denomina la regla 4 dB. It is not applied in the North American TIA Cabling Standards. Only certain test parameters and configurations will have the 4 dB rule. The tables below indicate which link  definitions and test parameters have the 4 dB rule applied to them. As an aid, the other rules are also listed.

Test Parameter

Clase D
Perm. Enlace

Clase E
Perm. Enlace

Clase EA
Perm. Enlace

Class F
Perm. Enlace

Class FA
Perm. Enlace

SIGUIENTE

PS NEXT

ACR-N

PS ACR-N

ACR-F

 

 

PS ACR-F

 

 

Pérdida de retorno

         
 
 

Test Parameter

Clase D
Canal

Clase E
Canal

Clase EA
Canal

Class F
Canal

Class FA
Canal

SIGUIENTE

PS NEXT

ACR-N

 

 

     

PS ACR-N

         

ACR-F

 

 

PS ACR-F

 

 

Pérdida de retorno

         

 
On a short link, the Insertion Loss may never reach 4,0 dB. Si eso ocurriera, entonces la medición entera sería omitida, o como las normas de cableado lo enuncian; "grabado solo para información". Si esto ocurriera con su DTX CableAnalyzer, vería una "i" junto al resultado del resumen para ese parámetro de comprobación. En el software LinkWare, el resultado se registraría con "N/A". Un ejemplo se muestra a continuación:
 

            Resultado de comprobación N/A destacado de software LinkWare    
 

La preocupación normalmente se produce cuando el resultado tiene un margen negativo. In this example we see the NEXT margin was -9,7 dB. A negative margin is normally associated with a FAIL, but because the entire link never exceeded 4,0 dB Insertion Loss, it's not a FAIL. Further confusion lies in that the North American ANSI/TIA/-568-C.0 cabling standard does not have this 4 dB rule. If you were to test the same link above with the same DTX CableAnalyzer, but using the North American Standard TIA Cat 5e Perm. Link, your result would be a FAIL.

            Autotest with Fail Result
 
Please make sure you have agreed in a Test Limit, in writing, before the project starts.
 
Let's review in detail how this works by looking at another example test result on the DTX CableAnalyzer.

An ISO11801 PL Max Class D AUTOTEST was run on a short 6,0 m installed link, giving the following result:
 
            Autotest with Pass Result
 
Looks normal. Let's take a look at the NEXT result in a little more detail:
 
            DTX CableAnalyzer NEXT Result

Usted verá que la línea de límite tiene dos colores, negro y rojo. Las normas de cableado no requieren que el fabricante del comprobador de cables muestre dónde se implementa la regla de 4 dB al usuario, solo que se está implementado. Sin embargo, el DTX CableAnalyzer indicará dónde se ha implementado la regla de 4 dB al cambiar el color de la línea de límite. If the limit line is black, the Insertion Loss was less than 4,0 dB. Si la línea de límite es roja, la pérdida de inserción fue de 4,0 dB o mayor. So for this Pair 1,2-4,5 the NEXT is not evaluated below 84,8 MHz. Let's take a quick look at the Insertion Loss for Pair 4,5:
  
            Resultado de pérdida de inserción de DTX CableAnalyzer
 
As you can see, the Insertion Loss reached 4,0 dB at 84,8 MHz, as previously indicated in the NEXT Pair 1,2-4,5 graph above. NEXT contains two pairs. So which Insertion Loss pair do we use to implement the 4 dB rule? The disturbed pair is used for evaluation purposes. So if the worst case NEXT Pair was 1,2-7,8 then the DTX CableAnalyzer would use the Insertion Loss values from Pair 7,8 to determine where the 4 dB rule is implemented.

As previously mentioned, if the link is particularly short, then the Insertion Loss may never reach 4,0 dB and the entire NEXT result is "ignored". Echemos un vistazo más de cerca al primer ejemplo donde el resultado de la comprobación fue:
 
            Ignored NEXT Result Screen

 
Looking at the worst case NEXT result, we see the entire limit line is black, suggesting that the Insertion Loss for Pair 4,5 never reached 4,0 dB: 
 
            Worst Case NEXT Result Screen
 
 
Observación de la pérdida de inserción para el par 4,5:
 
            Resultado de pérdida de inserción por debajo de 4 dB
 
Vemos que la inserción de hecho nunca llegó a 4,0 dB, por lo que toda la medición no se evalúa en la línea de límite (omitida) y se registra como "i" solo información. Si este resultado fue descargado al software LinkWare, el informe mostraría N/A contra esta medición:
 
            Highlighted N/A Measurement
 
El instalador no requiere ninguna acción adicional. Este es un resultado válido de cumplimiento de normas.

Autor: A.Young

Fecha de creación: 19-2-2014