Crónicas de cableado
Iluminando el camino para comunicaciones de luz visible
Lately it seems that there is a lot of attention surrounding digital lighting and the ability to power and control LED lights over the network infrastructure using Ethernet-based technologies like TCP/IP and PoE. While the benefits of LED lighting are becoming well known – energy efficiency, reduced installation and maintenance costs, and integration with IoT – there’s yet another benefit looming on the horizon.
4 de septiembre de 2019
Serie 101: configure el asistente de referencia.
When it comes to testing fiber systems, connector loss refers to the loss of a mated pair of connectors – it’s actually impossible to measure a single connector. To test the loss of the first connector, it must be mated to a similar, known quality connector. That’s where Test Reference Cords (TRCs) come in.
27 de agosto de 2019
Serie 101: Trenzado frente a Latiguillos sólidos
You’ve likely heard copper patch cords referred to as being constructed of either “stranded” or “solid” cable, but do you know the difference and which to choose when?
Just like the name implies, stranded four-pair cables are cables where each of the eight conductors of the four-pair cable are constructed of multiple “strands” of wires wrapped around each other, while solid cables are constructed with just one solid copper wire per conductor.
21 de agosto de 2019
7 razones para certificar
Cuando se trata de comprobar una instalación de cableado, básicamente existen tres opciones: verificación, cualificación y certificación. La verificación es excelente para la resolución de problemas, ya que le dirá si su cableado está conectado correctamente y puede ayudarle a encontrar roturas, conectores y empalmes. La cualificación le permite saber si el cable que se somete a comprobación admitirá una aplicación específica, lo que hace que sea ideal para pequeños movimientos, incorporaciones y cambios, o para determinar si una instalación del cableado existente puede admitir una aplicación (piense en una comprobación 2.5/5GBASE-T sobre una base instalada de Cat 6).
13 de agosto de 2019
Monomodo de corto alcance pone la reflectancia en el radar
La mayoría de nosotros somos conscientes de que los presupuestos de pérdida de inserción se han ajustado a medida que hemos pasado de 10 a 40/100 Gig para aplicaciones de fibra multimodo. One would think that we can’t say the same for single-mode applications that have historically meant larger loss budgets – 6.3dB for 100 Gig over singlemode (100GBASE-LR4) versus just 1.9dB for 100 Gig over multimode (100GBASE-SR4). But that’s no longer the case with new short-reach single-mode applications.
6 de agosto de 2019
Serie 101: ethernet vuelve a lo básico
Han transcurrido más de 40 años desde que Bob Metcalfe publicó este sencillo diagrama que explica su invención para interconectar ordenadores e impresoras en el Centro de Investigación de Xerox en Palo Alto, California. Su sistema patentado de conexión de datos multipunto con detección de colisiones luego se conoció como Ethernet.
31 de julio de 2019
Know the Punch Line
Installers have been punching down copper twisted-pair cable for decades and still do so for terminating cables to IDC towers on jacks, patch panels and connecting blocks. While the practice hasn’t changed, punchdown tools have come a long way, and you now have some options at your fingertips. So how do you choose? Echemos un vistazo más de cerca.
23 de julio de 2019
AV sobre par trenzado: ¿Qué necesito probar?
Ya sea videoconferencia o señalización digital, es probable que muchos de ustedes se enfrenten a solicitudes de sus clientes para desplegar plantas de cable que soporten sistemas audiovisuales.
Muchas de estas aplicaciones utilizan cableado de par trenzado, y los avances tecnológicos ahora permiten suministrar energía a las pantallas de vídeo simultáneamente con estas señales de vídeo a través del mismo cableado. Cuando se trata de implementar y probar las instalaciones del cableado necesarias para soportar estos sistemas AV, es importante entender las mejores prácticas de prueba para garantizar que sus clientes obtengan la imagen perfecta que esperan.
17 de julio de 2019
Aún no ha sido exactamente el centro de atención
Ha pasado un tiempo desde que hablamos sobre la fibra multimodo OM5 y, a pesar de su color verde lima y de su incorporación a la norma ANSI TIA-568.3-D en 2016, no ha sido exactamente el centro de atención, pero parece que ese no siempre será el caso.
10 de julio de 2019
Cabling Chronicles’ 4th of July Reflections
The 4th of July is always a time to reflect on our history, where we come from and the dedication of our founding fathers. But it’s also a time to look ahead, learn from past mistakes and progress towards a better future.
Our industry has a lot of history as well as traditional practices that we still use today simply because they work. But we also know that there are new ways of doing things, new parameters and new applications that are driving positive change.
1 de julio de 2019